Submitted by rvierdiiev
M-01 from previous audit is still present. In this issue, the sponsor said they fixed it. I tried to check how it was fixed, but the link doesnt work for me.
But change_gauge_weight function still exists which makes it possible to reproduce this. Also remove_gauge_weight function is present, that allows to completely remove gauge and i think that fix was to remove change_gauge_weight function.
Gauge can have bigger weight than was intended by protocol.
VsCode
Remove change_gauge_weight function.
Error
zjesko (Neobase) confirmed